Task Sequence Stops After Reboot

You can add location information to your Tweets, such as your city or precise location, from the web and via third-party applications. This is a continuation on how to invoke or trigger installations in Software center remotely with the help of Powershell. Marc 8 April 2015 at 21:01. Reboot OS. While this may be a good way to. You use the reboot command to shut down a single-user system and bring it into multi-user state. After that, enter your username and passwords followed by. Windows 10 Upgrade won't continue after reboot Tweet Ran into a problem today, during windows 10 inplace upgrade, machine didn't continue upgrade after reboot, it was about 70% of the update, machine shutdown and won't restart again. To extend or prevent the restart time on task sequence failure, use the "SMSTSErrorDialogTimeout" task sequence variable. However it does not have a reload option, and restart works different than we get used to. The Problem. That's it! Once the user logs in for the first time after the MBAM Client installs they will see a Microsoft BitLocker Administration and Monitoring screen pop up and they can kick off the encryption process or delay it up to one day. After some troubleshooting, I’ve found some of the main reasons…. That blog post can be found here. This may be a rare case, but if you are running in the same situation you can try the two options below:. To STOP Services. All you have to do is edit the ZTIDomainJoin. Popular Topics in Software Deployment & Patching. 19 thoughts on “ Task Sequence stuck ‘Installing’ in Software Center Task Sequence itself will ‘stop’ the ccmexec service during the upgrade, which then. Edit the Task Sequence 2. Originally, we had a separate Task Sequence for each office, and we'd have to pick the right one. Step 2: Deploy the task sequence to your systems. Hansen Experienced advanced operations engineer with a demonstrated history of working in the information technology and services industry. Evans 13 Comments By default an advertised Task Sequence in SCCM (Microsoft System Center Configuration Manager) will popup a message on the client workstation indicating that there is a new application that is available to be run. You try to reboot off the boot media and you see a message stating you can't restart the task sequence becuase its waiting for applications to load. Add a Restart computer task. I am facing a problem after the machine restart, the task sequence stop to run. Whenever you have a restart in a TS you can assume usually 2 - 5 minutes are added to the total TS time. Solutions: Step 1: Created Test collection and device imported with MAC ID and Target all the unknown computer deployment to new created test collection. Once I sat down and watched the task sequence I noticed that after IE11 was installed nothing happened, but a few applications later, something caused Windows to reboot. aspx Configuring TS for OSD Deployment SCCM 2012 Part 1. Just a little post for you showing the New Pop up notification for Update Microsoft Patch deployment (Whether or not a user is logged on option) with Center Configuration Manager 2012 ! In my quick example, i deploy more windows patch on a Windows XP SP3 client. This stopped the clients from receiving applications. Symantec helps consumers and organizations secure and manage their information-driven world. How to add custom scripts and task sequences to your MDT Bundle. In the smsts. Even though the task sequence may not require it, since the debugger requires user interaction, you need to sign in to Windows to continue. I've previously blogged about how you can re-run a required task sequence that is deployed to a client where it has for some reason failed. Also, when deploying the PreCache Task Sequence, make sure you do so with following settings. 1 node ; Right-click the Windows 8. ini is used while a little bit after, the task sequence variable value specified in the task sequence is being used. Powered by Blogger. This leaves you with 2 options. MDT 2013 Task Sequence Stops After Reboot - MS Security Essentials I was having quite the issue with one of my MDT images. The Setup program accepts optional command line parameters. I've created the ACFS filesystem following the steps carefully (or so I thought) only to have it vanish after a reboot. This is one of the problems that every SCCM (System Center Configuration Manager) admin will come across. The Deployment Bunny is at it again. After the system restarts, the workflow is resumed by a scheduled task, and the last step of producing a file containing data from the Win32_OperatingSystem class is performed. Tasks are commands that the task. Recently been setting up MDT 2013 Update 2 to push. I cannot figure how to accomplish this. A downside of giving a shutdown or restart command at the end of a TS is that SCCM will not log the TS as finished until the last task is peformed succesfully. Click on Add a Task and this will start the Scheduled Task Wizard. What should happen: Run the app. Another option to consider is the TSDisableProgressUI variable. 62 thoughts on " MDT - Put the domain join where it belongs. exe, but I don't know all the commands needed. MDT 2012 Part XI- How to Join Computer to Domain. Make sure to select The boot image assigned to this task sequence; After the restart, the BIOS will be configured with UEFI and Secure boot Only. I go over some basic unattend. 7, To reboot the target hosts, we need to define a block of code to reboot the server and wait until the hosts to come back. In our case, we are targeting a Windows 7 computer. Keep in mind this won't work everytime as it depends on where you failed your task sequence. The first thing we need to do is to stop MDT from performing the Domain Join during OS Setup. After the deletion action, the site remains in either an "active" or "deleting" state. However it does not have a reload option, and restart works different than we get used to. ConfigMgr will then take care of the reboot when needed. If you have started a task sequence in Configuration Manager and you hit a problem, the last thing you want to do is to have to go through the reboot process back into Windows PE. Follow through the remaining screens and when prompted, restart your computer. post-stop: where post-stop operations take place - to clean up; After the post-start state, the job is defined as running. If you come across this issue, here is how you fix it. We have a hardworking team of professionals in different areas that can provide you with guaranteed solutions to a blend of your problems. To extend or prevent the restart time on task sequence failure, use the "SMSTSErrorDialogTimeout" task sequence variable. In our environment, we have SCCM configured to force a restart after updates. Step 2: Deploy the task sequence to your systems. Solutions: Step 1: Created Test collection and device imported with MAC ID and Target all the unknown computer deployment to new created test collection. At some point in the TS, Mouse and Keyboard become nonresponsive. Resident Evil 5 and Resident Evil 6 had the unenviable task of existing in the same universe as Resident Evil 4. If the daemon stops doing that, the system is reset. When you're working with ConfigMgr 2012 and task sequences, these tend to fail now and then. Add a ‘Restart Computer’ Step after the above Step. You use the reboot command to shut down a single-user system and bring it into multi-user state. 2, and during the uninstall process the task sequence engine process is killed. Originally, we had a separate Task Sequence for each office, and we’d have to pick the right one. That way the application will be installed after deployment, when Group Policy is already active. This task sequence does not use any boot images, OS Installers/Images, or any other content normally required for OS deployment – just the two packages created during the import process. As soon as the timer. exe , restart again and run the othe customizations. After the Setup Windows Step of the Task Sequence (when the drivers are installed and Windows is booted for the first time), a reboot is initiated. It is very strange beacause the same task sequence wo. If you did some changes you want to keep an eye on under the installation, and you don’t have time to sit and watch the whole process, it’s very useful with a Pause step in your task sequence. It's pesky, but it is fixable! Several people have posted fixes for this issue, but I've seen their fix not work. First of all, there is one big negative point with MDT monitoring, that is the fact that its not historical. First you need to run the sysprep /oobe command after the image has been deployed to the device - and you need to be sure that the MDT task sequence has ended before you run sysprep /oobe. I can successfully "deploy" the image to any machine, but after the reboot, my task sequence doesn't continue, meaning the final task sequence deployment box doesn't open. ConfigMgr will then take care of the reboot when needed. So in a nutshell: when deploying a system using MDT 2012, at what point do the autologon items from unattend. Here is the task sequence: Restart in Windows PE. After that the system is rebooting and you can start all over again. Sometimes happen that you need SCCM services restart, like SMS_EXECUTIVE or other services. The task sequence cannot finish because in preparation of the image, BIS-F resets the SCCM client. I have customized the task sequence, which deploys the OS fine. If you have been using one task sequence for a while, changing to a new task sequence can cause trouble. This means the server would likely reboot into an unknown state and stop at a "No Operating System" prompt. Troubleshoot wasn't easy, especially do it remotely. exe , restart again and run the othe customizations. If I place a wire across contacts of X1 terminal OTGW communicate with boiler without any issues. Or set it to 0 for a timeout of 1,193,046 days. After that there is one more entry referring to loading TSRES. If I didn't do this, the user might start using an Office program after the. Please can you tell me how can I stop that running package? NOTE: Whenever I try to open that package it is hanging (Validating Sequence Container, where TransactionOption=Required) and then not able to do anything in BIDS. After digging around online, I came up with a solution. The first thing we need to do is to stop MDT from performing the Domain Join during OS Setup. I've created a build and capture SCCM OSD task sequence to deploy Win 7 Enterprise 32bit which runs fine until the first reboot. wsf script by "commenting out" the two lines that end with "true". After the restart happens, a user can log back into the system but has no way of knowing that a background process (the upgrade task sequence) is running. Stop Maintenance Mode This step is identical to step 3. After successfully executing the phase 1 and 2 BIOS update steps, the computer reboots and doesn't complete the remaining task sequence steps. How to Restart Windows Explorer Without Rebooting Computer. Task Sequence 2 Your 2nd Task sequence will format partitions etc etc and will then apply this WIM package. The only difference is that this step will set a maintenance mode of 1 minute. Use Unnattend. Tweet with a location. So here are all possible methods to disable automatic reboot after updates installation in Windows 10. Symantec helps consumers and organizations secure and manage their information-driven world. The mapping writes 50 rows to the target before Data Integration Service stops. My build & capture task sequence was identical to one I had used for Windows 8. This stopped the clients from receiving applications. On the bright side, you don't need deepfreeze anymore. After significant training, subjects would begin by performing a three-task sequence, and after completion of five cued sequences, would continue performing the same sequence, but without cues (Figure (Figure4B) 4B) in order to complete a block of trials (Figure (Figure4D). The Task Sequence fails on several (Havent tried all!) makes/models so not specific to any particular one. Unfortunately this task will fail in a spot where you cannot press F-8. Originally, we had a separate Task Sequence for each office, and we'd have to pick the right one. xml file configuration, but not much. The symptom is that no task sequences are available but the cause is because a device with the same guid as one of the unknown computers (x86 or x64) was created. Each time i launch mdt on a vm or a computer that already has windows on it, mdt just stops working after the first boot. Terminating active virtual applications would stop most change management, but halting productivity until a reboot is of course a deal-breaker. If you have been using one task sequence for a while, changing to a new task sequence can cause trouble. After the restart happens, a user can log back into the system but has no way of knowing that a background process (the upgrade task sequence) is running. I have seen some cases from aborted Task-Sequences where the device ended on the logon-screen and it was not visible if the Installation was complete or not. In Task Scheduler library, under “Microsoft” delete the “Configuration Manager” folder and any tasks within it. post-stop: where post-stop operations take place - to clean up; After the post-start state, the job is defined as running. Prior to Ansible engine 2. Go to Software Library \ Operating Systems \ Task Sequences; Right-click Task Sequences and select Deploy; On the General pane, select your collection. Leon Kennedy’s battle to save the President of the United States’ daughter from. Windows 10: SCCM Windows 1809 feature upgrade Task Sequence with OEM keys Discus and support SCCM Windows 1809 feature upgrade Task Sequence with OEM keys in Windows 10 Installation and Upgrade to solve the problem; Hello, in my company, we want to upgrade all laptops to Win 10 Pro 1809, primarily from Win 10 Pro 1607, 1703 and 1709). Posted by Onur Güzel 7 September 2012 22 Comments on Supervisord: Restarting and Reloading Supervisord is a great daemon for managing application processes. That blog post can be found here. Unfortunately, F8 doesn’t work at that point and I didn’t find any other way to terminate the process that was preventing the computer from booting up. Deploy the Task Sequence to your OSD collection and monitor its progress until it completes the installation. It only worked when the counter was at the last 15 minutes though. This blog post came about after i got a question from a user called Sonik o. Sccm - Run commands after restart to default operating Stackoverflow. I use my PC for rendering animations, and last night I set if. If you did some changes you want to keep an eye on under the installation, and you don’t have time to sit and watch the whole process, it’s very useful with a Pause step in your task sequence. Purely to provide the technical answer. Assuming you've enabled CMD prompt on your boot image, you can confirm this by hitting F8 to open the cmd prompt. In this scenario, the task sequence stops responding when the "Download of updates" message is displayed on the screen of the client computer. Word's Numbering Explained by John McGhie, MVP - comprehensive and not pretty (Downloadable pdf file in letter size) - Reading this is vital to anyone attempting to use automatic numbering or bullets in a law office setting or other places where the documents are likely to be reused or heavily edited. Of course, the task sequence partitions and formats the hard drive, so the boot image is immediately lost. Next thing is to add the command line to the task sequence: 1. Windows 10 Task Sequence In-Place Upgrade Stuck I created a task sequence to upgrade Windows 7 32bit to Windows 10 32bit. watchdog is such a daemon. Restart policies only apply to containers. Solution: Manually restart the WDS service. All operating systems freeze sometimes, and Ubuntu is no exception. [SCCM 2012] Task Sequence Hangs on Install Package During OSD (part 2) Posted on February 1, 2013 by windowsmasher So, in my previous post on the issue , I described a complicated series of hotfixes and WMI rebuild scripts which fix this serious issue. An application in your Task Sequence that is causing an unexpected reboot. Task Sequence 2 Your 2nd Task sequence will format partitions etc etc and will then apply this WIM package. The parallel task with sequence policy acts in a similar way to the sequence task. Set this variable to the desired timeout in seconds. Or set it to 0 for a timeout of 1,193,046 days. After you restart your computer, the uninstall tool automatically re-opens to complete the final step of the uninstall process. Marc 8 April 2015 at 21:01. Allposts inthis website are the property of PaddyMaddy &maynotbe reused inanyway without approval. As promised, this is my task sequence in details step-by-step. After restart, the system can be set to boot either into the task sequence's specified boot image or into the just installed default OS. Requirements. I have seen some cases from aborted Task-Sequences where the device ended on the logon-screen and it was not visible if the Installation was complete or not. Windows Explorer, also known as the Windows Shell, is the graphical user interface (GUI) that renders the Windows Explorer file manager, desktop icons, taskbar, task switcher, and. Lets face it, the Task Sequence progress bar is dated. First, identify your task sequence by ID. By Jeffery Hicks; 04/10/2012; It is a fact that Windows administrators periodically need to reboot servers and desktops. Fix 0x8000ffff Task Sequence by changing the equipment, after a device was installed in your pc, particularly when the problem occurs. In the environment, I am using a VMware vSphere virtual machine as my target for the deployment but sadly, the networks available to the host don. Amazon EC2 preserves the most recent 64-KB output which will be available for at least one hour after the most recent post. If all of the child tasks complete successfully, the parallel task returns with success. The Solaris reboot, poweroff, and halt commands stop the processor and synchronize the disks, but they perform unconditional shutdown of system processes. Then, when the task sequence finishes, you can automatically reboot the machine by adding FinishAction=RESTART to your CustomSettings. This is known as a locked-up or frozen state. In the end of the Task Sequence we have two groups, "OSD Completion" and "OSD Error". Sccm - Run commands after restart to default operating Stackoverflow. On the bright side, you don't need deepfreeze anymore. Support had me reinstall the ACFS libraries and that brought me up to the point where the underlying volume was in a DISABLED state. 3010), which is telling the ConfigMgr Client to prompt for a Restart. When deploying an OS image captured using a Build and Capture task sequence in Configuration Manager 1511 the client hangs on the client initialization step. Task sequences that have a restart action before an Install Packages action may fail. For this you can use the following PS-Script instead: Try { Set-ExecutionPolicy -ExecutionPolicy Bypass -Scope Process -Force -ErrorAction Stop } Catch {} # Stop Services Stop-Service -Name ccmsetup -Force -ErrorAction. The Task Sequence fails on several (Havent tried all!) makes/models so not specific to any particular one. A common challenge with Windows 10 Upgrade task sequences is handling user logins if there are any restarts during the task sequence. I’ve looked in the PullDP. Resolution To resolve this issue, we recommend that you apply any updates that require dual restarts by using the usual Software Updates feature of Configuration Manager instead of using task sequences. Update 30/10/2017: If SysPrep is consistently failing when building your Windows 10 1709 image, it is most likely due to the Windows Store update process updating the built in UWP apps. After this, my unattend file works perfectly and the task sequence handles the rest within MDT. TL;DR - When you attempt to upgrade Windows 7 to Windows 10 1709, the upgrade may hang at "Making sure you're ready to install", or if you are installing silently, SetupHost. I’ve tried. This stopped the clients from receiving applications. This will affect all IIS-dependent services. Microsoft Technology Tuesday, October 23, 2012 This is usually before a "Restart Computer" task, preferably towards the end of the Task Sequence after all. Assuming you've enabled CMD prompt on your boot image, you can confirm this by hitting F8 to open the cmd prompt. Restart policies for swarm. Adding a task is a matter of choosing the Add drop-down menu, choosing a task category, and then selecting the task. In our case, we are targeting a Windows 7 computer. Improvements to Run PowerShell Script task sequence step. It did install office, but after the in-application reboot it didn't resume the task sequence to perform a few other tasks that were part of my office bundle. The STOP task is triggered when the last value of the final sequence is loaded from RAM, and the peripheral stops at the end of the current PWM period. New Windows 10 works perfectly fine though. 2, and during the uninstall process the task sequence engine process is killed. If you have started a task sequence in Configuration Manager and you hit a problem, the last thing you want to do is to have to go through the reboot process back into Windows PE. Please can you tell me how can I stop that running package? NOTE: Whenever I try to open that package it is hanging (Validating Sequence Container, where TransactionOption=Required) and then not able to do anything in BIDS. com/en-us/evalcenter/hh667640. Is it possible to update the shutdown tool to be able to run from task sequence where you use task sequence to install applications and at the end force a reboot in 420 minutes out into the future? I currently have a hack in the task sequence to create a scheduled task on the machine:. The inbuilt Disable Bit L ocker task does not include a reboot count so BitLocker re-enables on next restart. In some cases it comes in handy to restart or shutdown your task sequence (TS) at the end of the TS. But technically communication works well. Task Sequence and shutdown (not reboot) a computer and continue For some reason there is a requirement to do a computer shutdown (not restart) while running a task sequence, and once the computer starts again there is a need to continue running the task sequence where we left it. How do I set my timetable such that my operators will complete the task on hand first before going for his break? Also my running time is from 0800-1800. exe , restart again and run the othe customizations. When updating Applications to a newer Version in ConfigMgr, you often need to deal with Restarts after a successful Installation. The task sequence takes a long time. log files is also not updated anymore after the last reboot. The Software Center shows a busy indicator and text to indicate that the task sequence is running, so after each restart, the Start Software Center after restart command starts Software Center back up so the user can see that the task sequence is still in progress. v1511 to v1607) is easy using the upgrade task sequence in SCCM. However, after the Setup Windows and ConfigMgr step, the machine will reboot, and you can use this reboot to install packages and also run command line steps. The second one was a sequence to install MS office 2010 Pro. After enabling and mounting the filesystem, all was good. Sometimes, Windows will restart the process automatically after a minute or so, but it’s easiest just to go ahead and restart it yourself. ConfigMgr will then take care of the reboot when needed. My Customer have MDT 2012 U1, so when he start a task sequence when the task start apply operating system, after the system restart and when the computer install the system the blue screen appear. SCCM 2012 - How to catch errors in Task Sequence Issue Description: A key requirement with a task sequence is to intelligently capture logs in case of a failure or a success. That way the application will be installed after deployment, when Group Policy is already active. You will need to increase the repeat frequency of the schedule. Hansen Experienced advanced operations engineer with a demonstrated history of working in the information technology and services industry. To have reliable installations of Office 2016 with no previous versions, we need to add one more component: a task sequence. After that configuration my WDS service start like a charm and we can start PXE booting again. Leon Kennedy’s battle to save the President of the United States’ daughter from. The latest version of Microsoft Deployment Toolkit (MDT) has been released today. Both boot images have been deployed to the distribution point and I can get the system to pick up a task sequence. Each time i launch mdt on a vm or a computer that already has windows on it, mdt just stops working after the first boot. But this can cause inconveniences to you. Let’s take a look at our task in the Active Tasks list. When this happens, and I open task manager, I can see that utorrent is using a lot of memory. After the restart happens, a user can log back into the system but has no way of knowing that a background process (the upgrade task sequence) is running. When you use Task Sequences (TS) to deploy software (non OS TS) and there is a reboot inside of the TS there will be no ProgressUI at the logon Screen after the reboot. Turns out this was due to one of the steps in the task sequence requiring a reboot. Open Task Scheduler by navigating the Windows Start menu to All Programs > Accessories > System Tools > Task Scheduler. To edit a task sequence after creation, right-click it and choose Edit (choosing Properties from the context-menu results in the Properties dialog box of the task sequence and not the task sequence editor). Create a [Mostly] Automated Reference Image in MDT - Part 5: Pause/Suspend the Task Sequence When it comes to deploying an operating system to a computer, speed and accuracy are the name of the game. That way the application will be installed after deployment, when Group Policy is already active. The Problem. There's a bug with unknown computers in 1702, in which a computer you previously built is using the GUID for the unknown computer. This is a simple option to select when you deploy the task sequence under the Distribution page (or tab) select "Download all content locally before starting task sequence" from the drop down menu. Restart policies only apply to containers. In some situations, restarting is completed after a few minutes, while in others the process might take hours. Requirements. This is designed to run directly on the SCCM Client machine. About Alex Ø. This is the. Tasks are commands that the task. After that there is one more entry referring to loading TSRES. For any of those interested, this is the SetupComplete CMD file Microsoft uses to complete the Task Sequence during a Windows 7-8 upgrade to Windows 10. My Customer have MDT 2012 U1, so when he start a task sequence when the task start apply operating system, after the system restart and when the computer install the system the blue screen appear. Follow through the remaining screens and when prompted, restart your computer. When this happens, and I open task manager, I can see that utorrent is using a lot of memory. com/profile/11996817461414163574. After that configuration my WDS service start like a charm and we can start PXE booting again. The software must request a restart using the standard restart code, 3010. When listing this information to the screen it was OK, but when sending it to a. If you need to do the job again on another document, paragraph or worksheet you have to run the macro again. Task sequences that have a restart action before an Install Packages action may fail. I did not do this during image capture; I added it to the Apply Operating System step of my task sequence. How can i resolve this problem?. A common challenge with Windows 10 Upgrade task sequences is handling user logins if there are any restarts during the task sequence. The task sequence step must set this task sequence variable if it requires the restart to complete the task sequence step. Also, when deploying the PreCache Task Sequence, make sure you do so with following settings. This means the server would likely reboot into an unknown state and stop at a "No Operating System" prompt. In this example I created a group named Prepare for running TS as different user and added the following actions: Run Command Line Name: Add Administrator001 user to local admin group. Deployment. The machine will install the OS and reboot back into a MDT task sequence. So, if you want to just restart the task sequence without rebooting, carry out the following steps:. I set this to ten minutes (600 seconds) in all of my OSD task sequences. The company i currently consult for also wanted me to implement MBAM (Microsoft Bitlocker Administration & Management) within their bitlocker infrastructure and Windows 10 rollout. A customer of mine had an incident where the TS hung because Hotfix KB2761938 wasn’t installed on the clients. I would think that after the hard shutdown, the task sequence was broken and didn't start again, but UPGBackground didn't self-destruct after 12 min. After the restart happens, a user can log back into the system but has no way of knowing that a background process (the upgrade task sequence) is running. To test that the task actually works, manually mess up your clock's time and then right-click the task and select Run. After you update to SCCM, version 1806, software updates do not download. Using the Deployment Workbench, in the MDT Production node, select the Task Sequences / Windows 8. - Task sequence name. A customer of mine had an incident where the TS hung because Hotfix KB2761938 wasn't installed on the clients. Additionally, after the user logs in, the task sequence progress bar may take a while to be shown again (or may never reappear). The company i currently consult for also wanted me to implement MBAM (Microsoft Bitlocker Administration & Management) within their bitlocker infrastructure and Windows 10 rollout. Solution: Manually restart the WDS service. I've recently been looking at using SCCM Windows Upgrade Task Sequences to migrate from Windows 10 1511 to Windows 10 1607 for a customer. Originally, we had a separate Task Sequence for each office, and we'd have to pick the right one. I applied an unattend file that hid WiFi setup, and disabled both user and computer OOBE. log will not change in size and will be under 200KB. It opens /dev/watchdog, and keeps writing to it often enough to keep the kernel from resetting, at least once per minute. Fix for SCCM Task Sequence shows Remove the CD and do not boot from CD. After the Setup Windows Step of the Task Sequence (when the drivers are installed and Windows is booted for the first time), a reboot is initiated. How to restart the task sequence wizard in WINPE without having to reboot If you make a mistake and cancel out the task sequence wizard in WinPE you can restart it without rebooting. cmd /quiet /sccm /ign /pass:xxxxxxxxxx You need to consider. The Task Sequence Name and. Does it work and serve a purpose, yes, does it look like Windows 98, heck yeah. Since last week, our task sequence just stopped working. It's pesky, but it is fixable! Several people have posted fixes for this issue, but I've seen their fix not work. - Task sequence security scope. System Center is still relatively new to our application development teams, so first I hope to develop trust in the tools, then move to automate these processes further via task sequences or Orchestrator run books. Task Sequence 2 Your 2nd Task sequence will format partitions etc etc and will then apply this WIM package. wsf that isn't actually part of any of the task sequence templates - by default it's not used. However, after the Setup Windows and ConfigMgr step, the machine will reboot, and you can use this reboot to install packages and also run command line steps. log file in one of the following locations. A computer restart is needed after the task sequence deployment to make Group Policy active on the system. This change lets you run PowerShell commands during a task sequence without first creating and distributing a package with the script. To edit a task sequence after creation, right-click it and choose Edit (choosing Properties from the context-menu results in the Properties dialog box of the task sequence and not the task sequence editor). This is a continuation on how to invoke or trigger installations in Software center remotely with the help of Powershell. Set this variable to the desired timeout in seconds. Immediately after the Format and Partition Disk task sequence step, identified in the previous step, create a task sequence step based on the Set Task Sequence Variable task sequence type to reset the use of the GPT disk partition system using the information in Table 2 to complete the Properties tab. Choose Add, General, Run Command Line Note: The user can't be added as all steps in the Install Operating System group are executed in WinPE. This is a problem if installing in a task sequence as a reboot will be forced even if you supress the reboot. It never even gets to the reboot in the Task Sequence from the logs or from watching the screen the entire time. After you update to SCCM, version 1806, software updates do not download. I can install other apps via Software Center as well without issues. This may be a rare case, but if you are running in the same situation you can try the two options below:. Configuration Manager 2012 OSD Fails After Restart 28th January 2014 richardjgreen I was working today testing the operating system deployment capability of System Center Configuration Manager 2012 (not R2) for a Windows 7 task sequence. Machines don't always start after scheduled Reboot I'm gonna try to bypass it and use a vmware restart task and see how it goes. I started seeing is issue, or at least these symptoms, recently with my win7 OSD TS in SCCM 2012R2. If the RTC is started from PPI(say some GPIOTE event assigned to PPI), I have no trouble with the STOP, CLEAR, START task sequence. If you want to provision the ConfigMgr client as part of your Task Sequence then unfortunately the first step in the process, net stop ccmexec (stopping the SCCM service) is going to kill the Task Sequence and it's game over. Restart Computer This uses the normal task sequence step 'Restart Computer' with the option: 6. inf file to use - Depending on the sysprep. To make sure MDT won’t stop anymore, we will add the registry key into our failing task sequence. Then, when the task sequence finishes, you can automatically reboot the machine by adding FinishAction=RESTART to your CustomSettings. So, by this time, MDT 2013 RTM release is an old news. This behavior makes sure that the task sequence properly handles the restart.